Process Control and Other Features:
1. STAINLESS STEEL 304 TRIPLE WALLED CONSTRUCTIONS:
- a) Triple walled design with mineral wool insulation for prevention of burn to users.
- b) Top quality stainless steel 304/316 construction including piping to avoid corrosion and contamination of.
2. Quick Hot Air Drying System:
- Specially Designed Drying Valves Have Been Provided to Ensure Each Load Comes Out Completely Dry.
3. State of the Art – Vacuum System:
- Vacuum Is a Must for Optimum Steam Penetration & Drying of Sterilization Load. Our “Steri” Vertical Steam Sterilizer Is Equipped with Cutting Edge Vacuum Which Sets Us Apart from Our Competition.
4. Automatic Low Water Cut Off System:
- The Machine Is Equipped with Water Detection System. When the Water Level Decreases Below a Threshold Then Heating Elements Will Automatically Turn Off. the User Will Be Notified in Case the Water Level Is Not Optimum for Regular Machine Operation.
5. Automatic Pressure Control System:
The Sterilizer Has Automatic Pressure Control Switch Which Automatically Maintain the Desired Pressure and Restricts Any Abnormal/ Unsafe Rise of Pressure in the Sterilizer.
6. Validation Port:
- The Sterilizer Is Equipped with External Validation Port for the Sterilizer Calibration.
7. Water Level Indicator:
- The Sterilizer Is Equipped with Water Level Gauge Glass to Indicate the Water Level.
8. Airtight Sealing:
- Heavy Duty Branded Silicon Gasket Will Be Provided for Airtight Seal.
9. Analogue Gauges:
- A) The Sterilizer Is Fitted with Branded Nabh Calibrated Analogue Chamber Pressure (Compound) Gauge to Measure the Pressure and Vacuum of Chamber.
- B) The Sterilizer Is Fitted with Branded Nabh Calibrated Analogue Jacket Pressure Gauge to Measure the Jacket & Boiler Pressure.
- C) The Sterilizer Is Fitted with Branded Nabh Calibrated Analogue Chamber Temperature Gauge to Measure and Indicate Temperature.
10. Safety Features:
10.1 Automatic Shut Off Valve:
- Prevents Hazardous Leakage of Hot Steam and Boiled Water Due to Breakage of Glass Tube.
10.2 Hydraulic Testing:
- Complete Sterilizer Including Chamber, Jacket, and Piping Are Hydraulically Tested at 2 Times the Working Pressure.
10.3 Vacuum Breaker:
- The Sterilizer Is Fitted with Vacuum Breaker System to Prevent Collapsing of Jacket Due to Vacuum Formed by Condensation of Steam.
10.4 Safety Valve:
- The Sterilizer Is Fitted with a Safety Valve.
10.5 Insulation:
- The Sterilizer Is Completely Insulated to Prevent Any Burns Caused Due to Accidental Contact to Sterilizer Body.