Mohan Nagar, Ghaziabad, Uttar Pradesh
1 piece (MOQ)
Business Type | Manufacturer, Exporter, Supplier |
Brand Name | Steri |
Material | Stainless Steel |
Driven Type | Electric |
Click to view more |
Preferred Buyer From
Location | Worldwide |
Product Details
Process Control and Other Features:
1. AUTOMATIC CONTROL SYSTEM:
The Machine is equipped with fully automatic control system. Having each function (10+) of autoclave automated such as:
a) Auto Water Feeding
b) Auto Pre Vacuum Pulsing
c) Auto Ster
d) Auto Slow Exhaust
e) Auto Fast Exhaust
f) Auto Vacuum Dry
g) Auto Filter Air Dry
h) Auto Door Locks
i) Auto Fault Detection & Notification System
j) Auto Shutdown
2. 6 PRE-PROGAMMED CYCLES:
a) 4 Sterilization Cycles
Instrument Cycle
Liquid Cycle
Fabric Cycle
Customer Variable Cycle:
The machine having user variable cycle will allow user to customize the temperature settings, pressure settings and vacuum pulse settings.
b) 2 Test Cycles
Bowie Dick Test Cycle
Leak Test Cycle
3. AUTOMATIC WATER FEEDING SYSTEM:
The Sterilizer has automatic water feeding system ensuring autoclave to run without any interruption.
4. AUTOMATICALLY DETECTS ANY CHAMBER LEAKAGE:
The Machine automatically detects any air/steam leakage in chamber.
The Machine automatically detects any steam penetration barriers, inadequate air removal.
5. OPTIONAL DATA STORAGE FACILITY:
Historical cycle data gets stored in the memory of sterilizer which can be easily retrieved at will through USB.
6. OPTIONAL PRINTING FACILITY:
a) The user can record the progress of the sterilization cycle in real time and print the following details:
Date and Time of the cycle.
Batch No.
Cycle Selected
Preset Cycle Parameter
Status of the cycle
Temperature and chamber pressure
b) It is capable of printing at desired time interval, minimum of 1 minute
c) All undesired situation (faults) are printed at the time of fault generation
Note: - Printer is available at extra cost with this model.
5. POWERFUL TRIPLE DRYING SYSTEM:-
a) WATER RING TYPE VACUUM PUMP:
Machine is equipped with Water Ring Type Vacuum Pump for complete drying load in both automatic & manual mode.
b) BACKUP VACUUM SYSTEM:
Machine is equipped with Cutting edge venturi system for creating vacuum in manual mode.
c) HOT AIR DRYING:
Specially designed drying valves have been provided to ensure each load comes out completely dry.
6. SAFETY FEATURES:
The sterilizer has various inbuilt safety feature which not only protects the user but also ensures the sterilizer is working as per design and identifies any inconsistency in the system. We have listed few such features below for your reference:
6.1 AUTOMATIC FAULT DETECTION AND ALARM SYSTEM:
The Machine is equipped with precision sensors capable of detecting various faults and notifying the user thereby making this a smart sterilizer:
a) AUTOMATIC DUAL DOOR LOCK AND DETECTION SYSTEM: It is an inbuilt feature where In case the doors are not closed properly the sterilizer prevents the user from starting the cycle and visually notifies the same
b) TEMPERATURE DETECTION SYSTEM: The user is notified in case the machine fails to reach the set temperature or if the temperature overshoots
c) AUTOMATIC PRESSURE DETECTION AND MAINTENANCE: Chamber & Jacket pressure is maintained automatically. In case the pressure fails to reach the set value or if it drops the user is notified
d) WATER DETECTION SYSTEM: The user will be notified in case the water level is not optimum for regular machine operation.
e) AUTOMATIC ELECTRICITY ECONOMIZER: Once the temperature is reached or water level is not at optimum level the sterilizer will automatically cut off the heater system to save electricity.
f) VACUUM LOCK DETECTION SYSTEM: this system detects the total vacuum generated and total time of vacuum maintained in chamber. It is also capable of detecting steam and air leakage.
g) POWER CUT CYCLE RETENTION AND MANAGEMENT SYSTEM: the machine is equipped to deal with any power outages and based on the duration of the power outage the user is notified.
6.2 PASSWORD PROTECTION:
a) The sterilizer settings are password protected.
b) The date and time settings are password protected, and User is able to update date and time settings on the screen for better record keeping.
6.3 EMERGENCY STOP:
An Easily Accessible emergency stop is provided on main control panel door.
6.4 POWER FAILURE:
Equipment settings will not get disturbed due to power failure and will not restart without human intervention.
6.5 HYDRAULICALY TESTED:
Complete sterilizer including chamber, jacket, and piping are hydraulically tested at 2 times the working pressure.
6.6 AUTOMATIC PRESSURE CONTROL SYSTEM:
The sterilizer has automatic pressure control switch which automatically maintain the desired pressure and restricts any abnormal/ unsafe rise of pressure in the sterilizer.
6.7 AUTOMATIC SHUT OFF VALVE:
Prevents hazardous leakage of hot steam and boiled water due to breakage of glass tube.
6.8 AUTOMATIC VACUUM BREAKER:
The sterilizer is fitted with vacuum breaker system to prevent collapsing of jacket due to vacuum formed by condensation of steam.
6.9 AUTOMATIC LOW WATER CUT OFF SYSTEM:
The machine is equipped with automatic low water cut-off system. When the water level decreases below a threshold then heating elements will automatically turn off. The user will be notified in case the water level is not optimum for regular machine operation.
6.10 AUTOMATIC DUAL DOOR LOCKING SYSTEM:
a) AUTOMATIC ELECTRONIC DOOR LOCK:
The sterilizer is fitted automatic electronic door locking mechanism system.
a) AUTOMATIC MECHANICAL DOOR LOCK:
The sterilizer is equipped with automatic mechanical door locking system which prevents the user to open the door until the atmospheric pressure is achieved inside the chamber.
6.11 DUAL SAFETY VALVE:
The sterilizer is fitted with spring loaded dual safety valves.
6.12 HEAT PROTECTION:
The sterilizer is completely insulated with chloride face mineral glass wool to prevent any burns caused due to accidental contact to sterilizer body.
6.13 STEAM LEAKAGE PROTECTION:
Heavy duty branded silicon gasket is provided for airtight seal to prevent any leakage of steam.
6.14 NABH CALIBRATED GAUGES:
All our gauges including pressure, compound and digital temperature gauge are calibrated & certified by Indian most trusted NABH lab certified.
7. SEPARATE STEAM GENERATOR:
The sterilizer has separate steam generator with manual water feed control valve, separate manual valve for water drain and water level indicator.
8. PRE VACUUM STERILIZATION:
All the air leaving the sterilizer prior to sterilization is treated in an secondary thermal chamber making the air sterile.
9. THERMAL STERILIZATION:
High temperature steam comes in contact with air leaving the chamber and then passes through high temperature effective heat exchanger which makes the air sterile and safe.
10. WATER LEVEL INDICATOR:
The sterilizer is fitted with water level gauge glass to indicate the water level.
11. EXTRA PORT FOR CALIBRATION AND VALIDATION:
The sterilizer is equipped with external port for the sterilizer calibration and validation.
12. FLUSH MOUNTING:
The machine is equipped with SS 304 flush mounting only (Front side) Non-Sterile side.
Hi! Simply click below and type your query.
Our experts will reply you very soon.